国产乱妇乱子视频在播放,一级特黄aaa大片在线观看视频,亚裔美女被黑人巨大进入,欧美丰满熟妇BBB久久久,无码AV大香线蕉伊人久久九色
【劍橋大學(xué)最新研究】TCD自動(dòng)探頭監(jiān)護(hù)系統(tǒng):TBI患者采用TCD獲得最優(yōu)腦灌注壓

摘自:Acta Neurochirurgica
作者:Frederick A. Zeiler & Marek Czosnyka & Peter Smielewski

摘要

2018年9月29日,劍橋大學(xué)Marek Czosnyka教授等人在最新一期的《Acta Neurochirurgica》發(fā)表最新研究:通過采用自動(dòng)探頭,可以獲得危重TBI患者的長程腦血流記錄,從而獲得基于TCD腦血管反應(yīng)指數(shù)的接近最優(yōu)的腦灌注壓。隨著自動(dòng)探頭技術(shù)的不斷進(jìn)步,更長的記錄成為可能,人員工時(shí)投入減少,TBI患者使用連續(xù)無間斷的TCD監(jiān)測(cè)將成為神經(jīng)多模態(tài)監(jiān)測(cè)的標(biāo)準(zhǔn)配置。

方法

 本研究通過配備自動(dòng)探頭監(jiān)護(hù)系統(tǒng)的經(jīng)顱多普勒系統(tǒng)DelicaEMS-9D(德力凱,中國深圳,http://www.roselline.com/html/en)進(jìn)行MCACBFV的TCD評(píng)估。該系統(tǒng)允許使用1.6MHz自動(dòng)TCD探頭連續(xù)長程記錄MCA CBFV,并具有糾正探頭移位的自動(dòng)校正算法。

    我們的目標(biāo)是同時(shí)記錄來自所有設(shè)備的3~4h的連續(xù)數(shù)據(jù)。由于常規(guī)TCD監(jiān)測(cè)時(shí)間的限制,以前我們小組關(guān)于各設(shè)備參數(shù)關(guān)系的工作只能記錄到0.5~1小時(shí)的連續(xù)數(shù)據(jù)。

    根據(jù)Delica自動(dòng)探頭的技術(shù)規(guī)格,1.6MHz多普勒探頭的熱指數(shù)小于1.0,在大多數(shù)情況下熱指數(shù)小于0.5。因此,根據(jù)英國醫(yī)學(xué)超聲協(xié)會(huì)提供的成人TCD指南,該裝置的熱指數(shù)在可能“無限”的TCD連續(xù)監(jiān)測(cè)時(shí)間范圍內(nèi)是可接受的,同時(shí)遵守“ALARA”原則。因此,使用該系統(tǒng)進(jìn)行長程監(jiān)護(hù),不存在組織發(fā)熱的問題。

結(jié)論

隨著自動(dòng)探頭監(jiān)護(hù)系統(tǒng)的應(yīng)用,重癥外傷性腦損傷患者進(jìn)行長程血流監(jiān)護(hù)成為可能,允許使用基于TCD的腦血管反應(yīng)指數(shù)來近似獲得最佳腦灌注壓。隨著自動(dòng)探頭技術(shù)的不斷發(fā)展,更長的血流監(jiān)測(cè)記錄成為可能,醫(yī)生投入工時(shí)大大減少,TBI患者使用連續(xù)無間斷的TCD監(jiān)測(cè)將成為神經(jīng)多模態(tài)監(jiān)測(cè)的標(biāo)準(zhǔn)配置。

Abstract
Individualized cerebral perfusion pressure (CPP) targets may be derived via assessing the minimum of the parabolic relationship between an index of cerebrovascular reactivity and CPP. This minimum is termed the optimal CPP (CPPopt), and literature suggests that the further away CPP is from CPPopt, the worse is clinical outcome in adult traumatic brain injury (TBI). Typically,CPPopt estimation is based on intracranial pressure (ICP)-derived cerebrovascular reactivity indices, given ICP is commonly measured and provides continuous long duration data streams. The goal of this study is to describe for the first time the application of robotic transcranial Doppler (TCD) and the feasibility of determining CPPopt based on TCD autoregulation indices.
Introduction
Continuous monitoring of cerebrovascular reactivity in traumatic brain injury (TBI) is becoming increasingly common in the multi-modal monitoring (MMM) of critically ill patients [10, 11, 16]. To date, support for such monitoring has arisen within international consensus statements [10, 16]. Such support is centered on what is considered the Bgold standard^continuous index, pressure reactivity index (PRx—correlation between intracranial pressure (ICP) and mean arterial pressure (MAP)) [11], given its association with global outcome in TBI and validation in experimental animal models against the lower limit of autoregulation [4, 23, 32]. Furthermore, literature supports the association of PRx-derived Bpersonalized^cerebral perfusion pressure (CPP) targets (referred to as CPP optimum or CPPopt) and global outcome[19].Numerous other continuous indices of cerebrovascular reactivity exist in the TBI literature [31, 32], derived from other invasive and non-invasive monitoring devices, including transcranial Doppler (TCD)-based measures. Indices based on TCD mean flow velocity (FVm) and systolic flow velocity (FVs) have been linked to global outcome in adult TBI [6, 22] and are known to be reasonably strongly associated with ICPderived indices, such as PRx [30, 33].
……。
Signal acquisition
Various signals were obtained through a combination of invasive and non-invasive methods. Arterial blood pressure (ABP) was obtained through either radial or femoral arterial lines connected to pressure transducers (Baxter Healthcare Corp.CardioVascular Group, Irvine, CA). ICP was acquired via an intra-parenchymal strain gauge probe (Codman ICP MicroSensor; Codman & Shurtleff Inc., Raynham, MA). Zeroing of the arterial line occurred at the level of the tragus during the course of this study.
Finally, TCD assessment of MCA CBFV was conducted via a robotic TCD system,the Delica EMS 9D (Delica, Shenzhen, China, http://www.roselline.com/html/en). This system allows for continuous extended duration recording of MCA CBFV, using 1.6 MHz robotically controlled TCD probes, with automated correction algorithms for probe shift.We aimed to record 3 to 4 h of continuous data from all devices simultaneously, given the previous work from our group on inter-index relationships focused on recording durations of only 0.5- to 1-h duration due to limitations of conventional TCD [22, 30]. Based on manufacturer specifications of the Delica robotic TCD system, the thermal index for the 1.6 MHz Doppler probes is less than 1.0, with the index less than 0.5 in most cases. As such, in keeping with the guidelines for adult TCD provided by the British Medical Ultrasound Society, the thermal index for the device is in the range acceptable for potentially Bunlimited^ TCD duration, while adhering to the principles of Bas low as reasonably achievable^(ALARA) [5, 12, 13]. Thus, there were no concerns with tissue heating as a result of the extended duration recordings using this system. Brain temperature, local or global, was not recorded in this patient cohort. Figure 1 displays the robotic TCD device and set up for recording in critical ill TBI patients.……

欲知具體研究過程,請(qǐng)點(diǎn)擊20181018135428274.pdf

国产乱妇乱子视频在播放,一级特黄aaa大片在线观看视频,亚裔美女被黑人巨大进入,欧美丰满熟妇BBB久久久,无码AV大香线蕉伊人久久九色